Error [DataDirect][ODBC Progress OpenEdge Wire Protocol driver] Socket closed when doing a Test Connect in ODBC to FIMS Datasource
  • 30 Aug 2023
  • Contributors
  • Dark
    Light
  • PDF

Error [DataDirect][ODBC Progress OpenEdge Wire Protocol driver] Socket closed when doing a Test Connect in ODBC to FIMS Datasource

  • Dark
    Light
  • PDF

Article summary

When doing a test connect on ODBC, the following error occurs:

 [DataDirect][ODBC Progress OpenEdge Wire Protocol driver] Socket closed

Answer:

This is a network error where the machine in question cannot connect on the port used for ODBC. Your IT department will need to look into the network error routing issue.
A common cause of this issue is that the SQL porat is blocked on the FIMS database server. Be sure that ports for SQL are allowed in the firewall of the FIMS database server:
  • TCP ports 2500 and 2501, 2600(SQL), 2699 (IGAM), 3000-5000
Workarounds include trying to connect on a different workstation, directly on the database server or terminal server:

How do I setup an ODBC Connection on my FIMS workstation?