- Print
- DarkLight
- PDF
Error Unknown Field or Variable name Legacy Type 201 when running FieldMaker Process
Article summary
Did you find this summary helpful?
Thank you for your feedback
When running the FieldMaker process compilation, users might receive one of the errors below:
**Error=** Unknown Field or Variable name- Legacy_Type (201)
**Error=** n:\found\fims\gui\system\encrypted\encryptedDataProcedures.i.could not understand
Steps To Duplicate:
- Open FieldMaker by going to Tools > System Utilities > FieldMaker Configuration
- Click on the Processes tab
- Choose Commit changes and click Run Process
- Compilation errors occur after selecting to Run Process
Answer:
This was caused by the database not being updated during the 14.60 upgrade. The upgrade was re-run and it was verified that after that both the FIMS version and the DB version both show 14.60 in FIMS help. Fieldmaker was committed now without errors, and the Fieldmaker fields now show correct.